Administrative data

First-aid measures

Description of first aid measures
After inhalation: fresh air.
After skin contact: wash off with plenty of water. Remove contaminated clothing.
After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist.
After swallowing: immediately make victim drink water (two glasses at most). Consult a physician.

Most important symptoms and effects, both acute and delayed
irritant effects

Indication of any immediate medical attention and special treatment needed
No information available.

Fire-fighting measures

Extinguishing media
Suitable extinguishing media
Water, Carbon dioxide (CO2), Foam, Dry powder
Unsuitable extinguishing media
For this substance/mixture no limitations of extinguishing agents are given.

Special hazards arising from the substance or mixture
Combustible material, Vapours are heavier than air and may spread along floors.
Forms explosive mixtures with air on intense heating.
Development of hazardous combustion gases or vapours possible in the event of fire.
Fire may cause evolution of:
hydrogen bromide

Advice for firefighters
Special protective equipment for firefighters
Stay in danger area only with self-contained breathing apparatus. Prevent skin contact by keeping a safe distance or by wearing suitable protective clothing.

Further information
Suppress (knock down) gases/vapours/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Advice for non-emergency personnel: Avoid substance contact. Do not breathe vapours, aerosols. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert.
Advice for emergency responders: Protective equipment see section 8.

Environmental precautions
Do not empty into drains.

Methods and materials for containment and cleaning up
Cover drains. Collect, bind, and pump off spills.

Take up with liquid-absorbent material (e.g. Chemizorb® ). Dispose of properly. Clean up affected area.

Handling and storage

Precautions for safe handling
Advice on safe handling
Observe label precautions.
Hygiene measures
Immediately change contaminated clothing. Apply preventive skin protection. Wash hands and face after working with substance.

Conditions for safe storage, including any incompatibilities
Storage conditions
Protected from light. Tightly closed.
Recommended storage temperature see product label.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters
Exposure controls
Engineering measures
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment.

Individual protection measures
Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.

Eye/face protection
Tightly fitting safety goggles

Hand protection
splash contact:
Glove material: Viton (R)
Glove thickness: 0,70 mm
Break through time: > 10 min

Respiratory protection
required when vapours/aerosols are generated.
Recommended Filter type: Filter A-(P2)
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

Environmental exposure controls
Do not empty into drains.

Stability and reactivity

Reactivity
Forms explosive mixtures with air on intense heating.


Chemical stability
The product is chemically stable under standard ambient conditions (room temperature) .

Possibility of hazardous reactions
Violent reactions possible with:
Alkali metals, Oxidizing agents

Conditions to avoid
Strong heating.
A range from approx. 15 Kelvin below the flash point is to be rated as critical.


Incompatible materials
no information available


Hazardous decomposition products
in the event of fire: See section 5.