Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
between 8th March 2004 and the 15th of June 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines and/or minor methodological deficiencies, which do not affect the quality of relevant results.
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Date of inspection: November 2002 Date of signature: March 2003
Type of method:
closed cup
Flash point:
118.6 °C
Atm. press.:
101.3 kPa
Flash point:
118 °C
Atm. press.:
99 kPa

The determination of the flash point of the test item was performed in accordance with the EEC directive 92/69, Part A, Methods for the determination of physico-chemical properties, A. 9 "Flash Point", EEC Publication No. L383, December 1992.

Due to potential polymerisation of the test item, a heating test was performed in a beaker prior to the preliminary test.

In the preliminary test a clear flash point was observed at a test item temperature of 118 deg C. Therefore, the main test was also performed in duplicate. A clear flash point was twice observed at a test item temperature of 118 deg C. The mean value was calculated to be 118 deg C at the actual atmospheric pressure of 99.0 kPa.

After correction for the atmospheric pressure, the flash point of 2 -(2 -Vinyloxyethoxy)ethyl acrylate was determined to be 118.6 deg C at 101.3kPa using the Pensky-Martens flash point apparatus.

Interpretation of results:
GHS criteria not met
Conclusions:
After correction for the atmospheric pressure, the flash point of 2 -(2 -Vinyloxyethoxy)ethyl acrylate was determined to be 118.6 deg C at 101.3kPa
Executive summary:

The flash point was carried out according to the A.9 guideline under the EEC Directive 92/69. After correction for the atmospheric pressure, the flash point of 2 -(2 -Vinyloxyethoxy)ethyl acrylate was determined to be 118.6 deg C at 101.3kPa.

Description of key information

The flash point of 2 -(2 -Vinyloxyethoxy)ethyl acrylate was determined to be 118.6 °C at 101.3kPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
118.6 °C

Additional information

The flash point was carried out according to the A.9 guideline under the EEC Directive 92/69. After correction for the atmospheric pressure, the flash point of 2 -(2 -Vinyloxyethoxy)ethyl acrylate was determined to be 118.6°C at 101.3kPa.