First-aid measures

Emergency measure - Inhalation: Using appropriate personal protective equipment, move
exposed subject to fresh air. If breathing is difficult or
ceases, ensure and maintain ventilation. Give oxygen as
appropriate. The exposed subject should be kept warm and at
rest. Obtain medical attention in cases of known or possible
overexposure, or with symptoms including chest pain,
difficulty breathing, loss of consciousness or other adverse
effects, which may be delayed.
Emergency measure - Eyes: Wash immediately with clean and gently flowing water.
Continue for at least 15 minutes. Obtain medical attention.
Emergency measure - Skin: Using appropriate personal protective equipment, remove
contaminated clothing and flush exposed area with large
amounts of water. Obtain medical attention if skin reaction
occurs, which may be immediate or delayed.
Emergency measure - Ingestion: Never attempt to induce vomiting. Do not attempt to give any
solid or liquid by mouth if the exposed subject is
unconscious or semi-conscious. Wash out the mouth with
water. If exposed subject is fully conscious, give plenty
of water to drink. Obtain medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water, dry powder or foam extinguisher.


Fight the fire from a safe distance or protected location.

Product arising from burning: The substance is combustible and will burn if involved in
a fire, evolving noxious fumes (eg carbon and nitrogen
oxides and phosphorous and fluorine containing compounds).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing
apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.


Wear appropriate personal protective equipment conforming to
the relevant national or international standards, as
mentioned in section 2.3.00.



Avoid dust formation. Absorb spillages of solutions with a
suitable inert material (eg. sand or soil).


Carefully transfer the spillage to waste containers, or use
a sealed industrial vacuum machine. Containers filled with
waste material must be labelled in the same way as the
original substance containers.



Clean the spillage area with water only if waste water can
be directed to an on-site waste water treatment system.



Dispose of waste material in accordance with local
regulations by incineration.

Handling and storage

Handling: The substance should be stored, handled and used under
conditions of good industrial hygiene and in conformity with
any local regulations in order to avoid exposure.



Engineering controls are necessary to reduce exposure to the
substance.



When exposure cannot be prevented or adequately controlled
appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate
international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical protective clothing to Standard EN368

Eye protection to Standard EN166.


Furthermore, when respiratory protective equipment has to be
used, it must be capable of adequately controlling
exposure, be suitable for the purpose, and conform to the
appropriate international or national standards, such as a
dust mask conforming to EN149 FFP1.



These measures should be regarded as a minimum.

Storage: Store away from moisture and sources of ignition.


Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: Double-lined fibre keg. 20 to 50 Kg of material per bag.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None.

Chemical reaction with water: None which is hazardous.

Dust explosion: Dusy Explosivity:


Group: A

Maximum Explosion Pressure: 7.5 bar

Maximum Rate of Pressure Rise: 256 bar/s

Kst: 69 bar.m/s

St Class: 1



Minimum Ignition Energy: >500 mJ



Minimum Ignition Temperature:


Dust Cloud: 560°C

Powder Layer: No ignition or exotherm observed up to 400°C

Dust explosion determined by test: Y

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will not occur. Recovery from
minor spillages or accidental discharge is not economically
or technically feasible, and such waste material will be
disposed of by incineration. In principle, it may be
possible to recover larger spillages of uncontaminated

material for subsequent use.

Industry - Possibility of neutralisation: The notification tests have shown that the substance is
harmful by prolonged oral ingestion. No chemical treatment

is practicable to neutralise the hazardous health
properties.


The dust hazard will be minimised by appropriate handling
and storage.


No chemical treatment is practicable to neutralise the

hazardous environmental properties.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: The substance should be disposed of by incineration by
burning under controlled conditions at a licensed waste
treatment processor in accordance with local regulations.
Stack gases should be scrubbed, because noxious fumes (eg.
carbon and nitrogen oxides and phosphorous and fluorine
containing compounds) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly
to the sewage system or the aqueous environment. However,
adverse effects on sewage treatment systems would be
unlikely.

Industry - Possibility of destruction - other: None.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: None.