First-aid measures

Emergency measure - Inhalation: Remove to fresh air.  Keep person warm and at rest.  If

breathing stops, begin artifical respiration.

Emergency measure - Eyes: Immediately flush eyes with plenty of water for at least 15

minutes.  Seek medical attention.

Emergency measure - Skin: Remove contaminated clothing.  Wash affected area with soap

and water.  Seek medical attention if irritation develops.

Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Dry chemical, foam or carbon dioxide extinguishers may be

used.

Product arising from burning: The substance is combustible and will burn if involved in a

fire, evolving noxious fumes (eg carbon and phosphorus

oxides). However, there is no experimental evidence to

support the anticipated combustion products.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards as

mentioned in section 2.3.10.

Absorb spillages of solutions with a suitable inert material

(eg sand or soil). Carefully transfer the spillage to waste

containers, or use a sealed industrial vacuum machine.

Containers filled with waste material must be labelled in

the same way as the original containers.

Clean the spillage area with water and detergent.

Dispose of waste material by incineration in accordance with

local regulations.

Handling and storage

Handling: The substance should be stored, handled and used in

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard EN374

Chemical resistant clothing to Standard EN368

Eye protection to Standard EN166

When necessary appropriate respiratory protection should be

used. e.g. a vapour mask conforming to EN405 FFA1.

The standards mentioned above should be regarded as a

minimum.

Storage: Store at around 40°C in a dry, well-ventilated area.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: 220 to 250 kg drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported.

Chemical reaction with water: None reported.

Dust explosion: There is no dust explosion hazard from this semi-solid

material.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment will not occur. Recovery from

minor spillages or accidental discharge is not economically

or technically feasible, and such waste material will be

disposed of by incineration or landfill. In principle, it

may be possible to recover larger spillages of

uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: The notification tests have shown that the substance is

notconsidered hazardous to health or the environment.

Industry - Possibility of destruction: controlled discharge: Not recommended.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

should be scrubbed, because noxious fumes (eg carbon and

phosphorus oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not normally be discharged directly to

the sewage system or the aqueous environment. However,

adverse effects on sewage treatment systems would be

unlikely.

Public at large - Possibility of recovery/recycling: Not applicable as the neat substance will not be made

available to the general public.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Finished products containing small amounts of the substance

bound into polyurethane foam may be disposed of via

landfill.

Public at large - Possibility of destruction - incineration: Not applicable.