Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 04, 1996 - November 06, 1997
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study has been performed according to OECD and EC guidelines and according to GLP principles.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1997
Report date:
1997

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
other: Directive 92/69/EEC, A.6
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
GLP compliance:
yes (incl. QA statement)
Type of method:
flask method

Test material

Constituent 1
Details on test material:
- Name of test material (as cited in study report): Nikkol VC-IP
- Substance type: Colourless to light yellow transparent liquid
- Physical state: Liquid
- Stability under test conditions: stable
- Storage condition of test material: In refrigerator in the dark

Results and discussion

Water solubility
Water solubility:
< 0.09 mg/L
Temp.:
19 °C
pH:
ca. 7.5
Details on results:
Since NIKKOL VC-IP is a liquid, the column elution method as mentioned in OECD 105 and EEC A.6 guidelines is not applicable for the
determination of the water solubility. In order to find out if the flask method as mentioned in the guidelines is applicable, a preliminary test was
performed.

Applicant's summary and conclusion

Conclusions:
Interpretation of results (migrated information): insoluble (< 0.1 mg/L)
The water solubility of NIKKOL VC-IP at 19.0 ± 1.0°C is < 0.09 mg/l.