Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove to fresh air. If breathing is difficult or ceases,

give oxygen or mouth to mouth resuscitation. Keep warm and

at rest. Obtain medical attention.

Emergency measure - Eyes: Wash thoroughly with water and continue for at least 15

minutes. Seek medical attention.

Emergency measure - Skin: Remove contaminated clothing and launder before reuse.

Thoroughly wash all affected areas with soap and water. Seek

medical attention.

Emergency measure - Ingestion: Wash out mouth and give large quantities of water to drink.

Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Water spray, foam, carbon dioxide or dry powder.

Product arising from burning: The substance is combustible and will burn when subjected to

heat or a flame, evolving noxious fumes (eg carbon and

nitrogen oxides).

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards, as

mentioned in section 2.3.10.

Avoid dust formation by damping down with water. Absorb

spillages of solutions with a suitable inert material (eg.

sand or soil). Carefully transfer the spillage to waste

containers, or use a sealed industrial vacuum machine.

Containers filled with waste material must be labelled in

the same way as the original substance containers.

When as much as possible of the spillage has been collected,

flush the spillage area with copious amounts of water to an

effluent drain.

If the spillage was in an enclosed or partially enclosed

area, thoroughly ventilate and test the area before allowing

reacess.

Dispose of waste material in accordance with local

regulations by incineration.

Handling and storage

Handling: The substance should be stored, handled and used under

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure by

ingestion, inhalation, skin or eye contact.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

operators involved in the handling of the substance should

wear an air-fed protective suit designed to protect the head

and skin, plastic gloves and rubber boots.

Such protective equipment should conform to the appropriate

international or national standards.

Furthermore, when respiratory protective equipment has to be

used, it must be capable of adequately controlling exposure,

be suitable for the purpose, and conform to the appropriate

international or national standards.

These measures should be regarded as a minimum.

Storage: Store in a dry well ventilated area, at or below room

temperature in clearly labelled, sealed containers. Keep

containers tightly closed when not in use.

Packaging of the substance and or preparation: Double plastic bags within a fibre drum.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None known.

Chemical reaction with water: None which is hazardous.

Dust explosion: There is a potential dust explosion hazard for this organic

powder.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: The substance will be consumed during normal usage. Recovery

methods from minor spillages or accidental discharge are not

available. All waste arising from spillage or accidental

discharge will be incinerated at a licensed site.

Industry - Possibility of neutralisation: This substance is not associated with any hazardous chemical

effects. There are no established chemical treatment regimes

to neutralise hazardous health or environmental properties.

Industry - Possibility of destruction: controlled discharge: There will be no discharge of the substance during normal

usage.

Industry - Possibility of destruction - incineration: Any waste will be incinerated by burning in a licensed

incinerator in accordance with local regulations.

Industry - Possibility of destruction - water purification: There will be no discharge of the substance during normal

usage.

Public at large - Possibility of recovery/recycling: Not applicable.

Public at large - Possibility of neutralisation: Not applicable.

Public at large - Possibility of destruction: controlled discharge: Not applicable.

Public at large - Possibility of destruction - incineration: Not applicable.

Public at large - Possibility of destruction - water purification: Not applicable.

Public at large - Possibility of destruction - others: Not applicable.