Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Emergency measure - Inhalation: Remove to fresh air. If irritation occurs seek medical

attention.

Emergency measure - Eyes: Wash with water for 15 minutes. If irritation occurs seek

medical attention.

Emergency measure - Skin: Remove contaminated clothing and launder before re-use. Wash

skin with soap and water. If irritation occurs seek medical

attention.

Emergency measure - Ingestion: Seek medical attention.

Fire-fighting measures

Recommended extinguishing agent: Carbon dioxide, water spray or dry foam.

Product arising from burning: Products of combustion may contain oxides of carbon.

Product determined by test: N

Protective equipment: Full protective clothing and self-contained breathing

apparatus must be worn.

Fight the fire from a safe distance or protected location.

Accidental release measures

Emergency measures in case of spillage: Evacuate personnel from immediate vicinity.

Wear appropriate personal protective equipment conforming to

the relevant national or international standards.

Absorb spillages of solutions with a suitable inert material

(eg. sand or soil). Carefully transfer the spillage to waste

containers, or use a sealed industrial vacuum machine.

Containers filled with waste material must be labelled in

the same way as the original substance containers.

Clean the spillage area with water. Do not wash to drain.

Dispose of waste material in accordance with local

regulations by incineration.

Handling and storage

Handling: The substance should be stored, handled and used under

conditions of good industrial hygiene and in conformity with

any local regulations in order to avoid exposure.

Engineering controls are necessary to reduce exposure to the

substance.

When exposure cannot be prevented or adequately controlled

appropriate personal protective equipment should be worn.

Such protective equipment should conform to the appropriate

international or national standards as follows;

Chemical protective gloves to Standard prEN374

Chemical protective clothing to Standard EN368

Eye protection to Standard prEN166.

Furthermore, when respiratory protective equipment has to be

used, it must be capable of adequately controlling exposure,

be suitable for the purpose, and conform to the appropriate

international or national standards, such as a vapour mask

conforming to EN405 FFA1.

These measures should be regarded as a minimum.

Storage: Store in a cool dry well-ventilated room.

Keep containers tightly closed when not in use.

Packaging of the substance and or preparation: 200kg carbon steel drums.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

Shippingopen allclose all
Special provisions / remarks
Remarks:
Transport code: None
Transport: Avoid crushing the containers. In the event of a spillage,
observe the warning labels on the container.
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Stability and reactivity

Danger other than fire: None reported

Chemical reaction with water: None which is hazardous.

Dust explosion: Not applicable to a liquid.

Dust explosion determined by test: N

Disposal considerations

Industry - Possibility of recovery/recycling: Discharge to the environment should be avoided. Recovery

from minor spillages or accidental discharge is not

economically or technically feasible, and such waste

material will be disposed of by incineration. In principle,

it may be possible to recover larger spillages of

uncontaminated material for subsequent use.

Industry - Possibility of neutralisation: None known

Industry - Possibility of destruction: controlled discharge: Contaminated containers or spillages of solutions mixed with

inert material (eg. sand or soil) may be disposed of by

landfill at an authorised tip in accordance with local

regulations.

Industry - Possibility of destruction - incineration: The substance can be disposed of by incineration by burning

under controlled conditions at a licensed waste treatment

processor in accordance with local regulations. Stack gases

should be scrubbed, because noxious fumes (eg. carbon

oxides) could be formed.

Industry - Possibility of destruction - water purification: The substance should not be discharged directly to the

sewage system or the aqueous environment.

Public at large - Possibility of recovery/recycling: The substance will only enter the public domain in the form

of painted articles which can be disposed of as domestic

waste.

Public at large - Possibility of neutralisation: Not applicable as 100% of the substance used in industry.