First-aid measures

General information: If symptoms persist or in case of doubt, seek medical advice.

After inhalation: Supply fresh air; consult a doctor in case of pain.

After skin contact: Wash with water and soap. If symptoms persist, consult a doctor.

After eye contact: Rinse opened eye for several minutes under running water.

If symptoms persist, consult a doctor.

After swollowing: Rinse mouth with water.

Never give anything by mouth to an unconscious person.

Seek medical treatment.

Most important symptoms and effects, both acute and delayed: No further relevant information.

Indication of any immediate medical attention and special treatment needed: Dymptomatic treatment.

Fire-fighting measures

Extinguishing media

Suitable extinguishing agents: Foam, Fire-extinguishing powder, Carbon dioxide (CO2).

Use fire fighthing measures that suit the environment.

For safety reasons unsuitable extinguishing agents: Water.

Special hazards arising from the substance or mixture:

In case of fire, the following can be released: Noxious gases/vapours.

Advice for fire fighters:

Protective equipment: Wear self-contained respiratory protective device.

Additional information: Dispose of fire debris and contaminated fire fighting water ain accordance with official regulations.

Collect contaminated fire fighting water separately. it must not enter the sewage system.

Accidental release measures

Personal precautions, protective equipment and emergency procedures:

Wear protective clothing.

Product forms slippery surface when combined with water.

Particular danger of slipping on leaked/spilled product.

Environmental precautions:

Do not allow to enter sewers/surface or ground water.

Inform respective authorities in case of seepage into water course or sewage system.

Do not allow to penetrate the ground/soil.

In case of seepage into the ground inform responsible authorities.

Methods and material for containment and cleaning up:

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Make sure to recyle or dispose of in suitable receptacles.

Handling and storage

Precautions for safe handling:

No special precautions necessary if used correctly.

Ensure good ventilation/exhaustion at the workplace.

Avoid contact with eyes and skin.

Information about protection against explosions and fires:

Keep ignition sources away- Do not smoke.

Observe the general rules of industrial fire protection.

Conditions for safe storage, including any incompatibilities:

Requirements to be met by storerooms and receptacles:

Store container tightly sealed at a cool and dry place with sufficient ventilation.

Information about storage in one common storage facility:

Store away from foodstuffs. Store away from feed.

Storage class: 10 Combustible liquids.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Additional information about design of technical systems:

Install appropriate mechanical ventilation.

Control parameters:

Components with limit values that require monitoring at the workplace: Not required.

Additional information: The lists that were valid during the creating were used as basis.

Exposure controls:

Personal protective equipment:

General protective and hygienic measures:

The usual precautionary measures should be adhered to when handling chemicals.

Wash hands before breaks and at the end of work.

Breathing equipment:

under normal conditions of use not required.

At formation of aerosols and mist:

Short term filter device: Filter A (colour code: brown), Filter A/P2, Full mask with filter: ABEK-P2

Protection of hands:

Chemical resistant gloves.

The glove material has to be impermeable and resistant to the product/substance/preparation.

Due to missing tests no recommendation to the glove material can be given for the product/preparation/chemical mixture.

Selection of the glove material in consideration of the penetration times, rates of diffuision and the degradation.

Material of gloves:

The selection of suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer.

Penetration time of glove material:

The exact penetration time has to be found out by the amufacturer of the protective gloves and has to be observed.

For the permanent contact gloves made from the following materials are suitable:

Nitrile rubber, NBR

(Thickness: 0.35mm; Permeation time >=480 minutes)

Butyl rubber, BR

(Thickness: 0.5mm; Permeation time >= 480 minutes)

Eye protection: safety glasses.

Body protection: Protective work clothing.

Stability and reactivity

Reactivity:

Chemical stability:

Thermal decomposition / conditions to be avoided:

To avoid thermal decomposition do not overheat.

No decomposition if used and stored according to specifications.

Possibility of hazardous reactions: No dangerous reactions known.

Conditions toavoid: Strong heating, chemical contamination, sunlight, UV or ionizing radiation.

Incompatible materials: No further relevant information available.

Hazardous decomposition products:

No hazardous decomposition products if instructions for storage and handling are followed.

Disposal considerations

Waste treatment methods:

Recommendation: Adhering to the official regulations, it can be disposed of in an appropriate incinerator.

Uncleaned packagings:

Recommendation: Disposal must be made according to official regulations.