Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: guidance followed, no GLP

Data source

Referenceopen allclose all

Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
GLP compliance:
no
Type of method:
photocell detection

Test material

Constituent 1
Reference substance name:
Naphtha (coal), distn. residues
EC Number:
292-636-2
EC Name:
Naphtha (coal), distn. residues
Cas Number:
90641-12-6
Molecular formula:
Not applicable for UVCB substances
IUPAC Name:
1,2,3,4-tetrahydronaphthalene; 1,2-dihydroacenaphthylene; 1-methylnaphthalene; 2-methylnaphthalene; naphthalene

Results and discussion

Boiling pointopen allclose all
Boiling pt.:
ca. 235 °C
Atm. press.:
ca. 101 325 Pa
Decomposition:
no
Remarks on result:
other: nehyzb
Boiling pt.:
ca. 223.7 °C
Atm. press.:
ca. 101 325 Pa
Decomposition:
no
Remarks on result:
other: hyzb

Any other information on results incl. tables

first sample (nehyzb):

Correction of boiling point: YES

Standard deviation: 0.4 °C

Average boiling point: 235.0 ± 0.4 °C at 101.325 kPa

second sample(hyzb):

Correction of boiling point: YES

Standard deviation: 0.3 °C

Average boiling point: 223.7 ± 0.3 °C at 101.325 kPa

Applicant's summary and conclusion

Conclusions:
boiling point could vary due to variable composition