Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water

Description of key information

Flammable solids

Data waiving: The study does not need to be conducted since the substance is a liquid.

Flammable gases in contact with water

Data waiving: The practical experience of the sponsor and the test facility shows that no gases are developed, when the test substance is in contact with water.

Pyrophoricity

Data waiving: The test was not performed experimentally because practical experience exists at the sponsor and the test facility, e.g. when handling small amounts of the test substance repeatedly in air during testing. The test substance is therefore regarded as not being pyrophoric.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Justification for classification or non-classification

No flash point was observed up to the boiling point of the substance (ca 110 ºC).
The practical experience of the sponsor and the test facility shows that no gases are developed, when the test substance is in contact with water and the substance.
The substance is not pyrophoric based on practical experience at sponsor and test facility e.g. when handling small amounts of the test substance repeatedly in air during testing.

Based on these information, the substance is not classified for flammability according to CLP Regulation (EC) no. 1272/2008.