Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
viscosity
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Acceptable, well-documented study report which meets basic scientific principles. No GLP lab.
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
other: ASTM D 7042
GLP compliance:
no
Remarks:
No GLP certified lab
Type of method:
other: Stabinger viscometer
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
2.05
Conclusions:
The measured viscosity at 20°C is 2.05 mm2/s according to ASTM D 7042 methodology.
Executive summary:

The measured viscosity at 20°C is 2.05 mm2/s according to ASTM D 7042 methodology.

Endpoint:
viscosity
Type of information:
read-across from supporting substance (structural analogue or surrogate)
Adequacy of study:
key study
Study period:
2009
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with ASTM D 446-07 testing method.
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
other: ASTM D 446-07
Deviations:
no
GLP compliance:
no
Remarks:
Not specified
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
1.66
Conclusions:
The measured viscosity at 20°C is 1.66 mm2/s.
Executive summary:

The viscosity of the Hydrocarbons, C10-C13, n-alkanes, <2% aromatics has been measured following the ASTM D 446-07 testing method. The result at 20°C is 1.66 mm2/s.

Description of key information

The kinematic viscosity of Hydrocarbons, C10-C13, n-alkanes, <2% aromatics, measured in accordance with ASTM D 445 method, is between 1.5 and 2.0 mm2/s at 20°C.

The viscosity of Hydrocarbons, C10-C13, isoalkanes, cyclics, <2% aromatics at 20°C is between 1.0 and 2.3 mm2/s.

The viscosity of Hydrocarbons, C10-C13, n-alkanes, isoalkanes, cyclics, <2% aromatics at 20°C is 1.3 to 2.5 mm2/s according to the ASTM D 7042 testing methodology.

This data is used for read across to Alkanes, C10-13-iso-.

Key value for chemical safety assessment

Additional information