Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-07-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: According to OECD Guideline

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
GLP compliance:
no
Type of method:
capillary method

Test material

Constituent 1
Chemical structure
Reference substance name:
3,4,5,6,7,8,9,10,11,12,13,14-dodecahydro-2H-cyclododeca[b]pyran
EC Number:
251-090-5
EC Name:
3,4,5,6,7,8,9,10,11,12,13,14-dodecahydro-2H-cyclododeca[b]pyran
Cas Number:
32539-83-6
Molecular formula:
C15H26O1
IUPAC Name:
2H,3H,4H,5H,6H,7H,8H,9H,10H,11H,12H,13H,14H-cyclododeca[b]pyran
Details on test material:
- Name of test material (as cited in study report): Bicyclenoxyde
- Substance type: active substance
- Physical state: viscous liquid
- Isomers composition: not concerned
- Purity test date: 2009-04-21
- Lot/batch No.: R035090421
- Storage condition of test material: at 4°C in the dark

Results and discussion

Melting / freezing point
Melting / freezing pt.:
ca. -9 °C
Atm. press.:
ca. 973 hPa

Applicant's summary and conclusion

Conclusions:
The freezing temperature for the test material determined following the A1 Method of Council Regulation 440/08/EEC and Method 102 of OECD Guidelines for Testing of Chemicals is -9 °C at 973 hPa (P atmospheric).
Executive summary:

The freezing temperature for the test material determined following the A1 Method of Council Regulation 440/08/EEC and Method 102 of OECD Guidelines for Testing of Chemicals is -9 °C at 973 hPa (P atmospheric).