Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6 Nov 2017 to 25 Mar 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
Version / remarks:
Estimation method was used.
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient - Shake Flask Method)
Version / remarks:
Estimation method was used.
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7550 (Partition Coefficient, n-octanol / H2O, Shake Flask Method)
Version / remarks:
Estimation method was used.
Deviations:
no
GLP compliance:
yes
Type of method:
estimation method (solubility ratio)
Partition coefficient type:
octanol-water
Type:
log Pow
Partition coefficient:
< -5.1
Temp.:
19.9 °C
Remarks on result:
other: Estimation method
Remarks:
based on water solubility and n-octanol solubility

Results

n-Octanol solubility test

The content of test item dissolved in the n-octanol sample was 8.25 mg/L.

Estimation Method

The water solubility of the test item was > 1003 g/L. Based on the results for water solubility and n-octanol solubility, the Pow value of the test item is < 8.3 x 10-6.  This corresponds with a log Pow value of < -5.1. Therefore, no further testing was performed and estimation method was applied instead of the shake flask method.

 

Conclusion

Since Pow appeared to be very low, the estimation method was applied for the determination of the partition coefficient (Pow) of CD-3 / CAS 25646-71-3. The Pow value of the test item is < 8.3 x10-6.  It corresponds with a log Pow value of < -5.1.

Description of key information

Log Pow value is < -5.1 at 19.9 °C (OECD 107, estimation method).

Key value for chemical safety assessment

Log Kow (Log Pow):
-5.1
at the temperature of:
19.9 °C

Additional information

The partition coefficient of the target substance was additionally evaluated by means of (Q)SAR models, using the organic fragment of the substance as representative structure. The log Pow values as estimated by the three models present in VEGA v1.1.3 are reported in the following table. The two most similar substances identified by VEGA are also included (using their CAS number), together with their similarity degree with the target component, experimental log Pow values and the predictions obtained by the QSAR models.

 

Molecule / CAS

Similarity degree

Experimental log Pow

VEGA / ALogP

VEGA / Meylan-KOWWIN

VEGA / MLogP

Target / 25646-71-3

-

n.a.

1.58

1.34

1.38

Similar / 97141-32-7

0.846

2.13

2.307

1.915

1.979

Similar / 97141-29-2

0.845

1.45

1.394

0.933

1.426

 

With respect to the calculated applicability domain index (AD Index = 0.85), the substance is suspected to be not fully compliant with the applicability domain of the three models. The performances on the similar molecules are however generally good (only the Meylan-KOWWIN prediction for 97141-29-2 gave moderate performance).

 

Based on the obtained results, the log Pow of the target substance can be estimated as the average between the three obtained predictions, resulting as log Pow = 1.43.