Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
yes
Remarks:
Standard water pH 8 ISO 6341 OECD TGD 29
GLP compliance:
yes (incl. QA statement)
Type of method:
flask method
Water solubility:
< 1 µg/L
Temp.:
20 °C
pH:
8

Fe < 1 µg/L at 1 g iron manganese trioxide/L and Fe = 1 µg/L at 10 g iron manganese trioxide/L

Mn 186 µg/l at 1 g iron manganese trioxide/L, Mn 648 µg/L at 10 g iron manganese trioxide/L

Conclusions:
Interpretation of results (migrated information): insoluble (< 0.1 mg/L) concerning Fe
Iron insoluble (< 0.1 mg/L)
Mn slightly soluble (< 1 mg/L)
Executive summary:

The determination was performed according to OECD Guideline 105 at pH 8.

For the determination six test mixtures with two different loading concentrations (1 g/l and 10 g/l) were agitated with a magnetic stirrer for 24 hours at 20 °C. The received suspensions were filtrated through a

0.1 μm (100 nm) membrane filter. Also three blank solutions (standard water pH 8 to ISO 6341, OECD-Guidance-Document 29) were investigated.

After filtration of all mixtures and blank solutions iron- and manganese determination was performed in each filtrate with Graphite Furnace Atomic Absorption Spectrometry (GFAAS).

The water solubility was very low with:

Fe < 1 µg/L at 1 g iron manganese trioxide/L and Fe = 1 µg/L at 10 g iron manganese trioxide/L

Mn 186 µg/L at 1 g iron manganese trioxide/L, Mn 648 µg/L at 10 g iron manganese trioxide/L

Description of key information

The water solubility of iron manganese trioxide at 20°C was determined to be </= 1 µg/L concerning Fe.

Key value for chemical safety assessment

Additional information

The determination was performed according to OECD Guideline 105 at pH 8. For the determination six test mixtures with two different loading concentrations (1 g/L and 10 g/L) were agitated with a magnetic stirrer for 24 hours at 20 °C. The received suspensions were filtrated through a 0.1 μm (100 nm) membrane filter. Also three blank solutions (standard water pH 8 to ISO 6341, OECD-Guidance-Document 29) were investigated. After filtration of all mixtures and blank solutions iron- and manganese determination was performed in each filtrate with Graphite Furnace Atomic Absorption Spectrometry (GFAAS).

The water solubility was very low with:

Fe < 1 µg/L at 1 g iron manganese trioxide/L and Fe = 1 µg/L at 10 g iron manganese trioxide/L

Mn = 186 µg/L at 1 g iron manganese trioxide/L, Mn = 648 µg/L at 10 g iron manganese trioxide/L