Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Description of key information

Skin and eye irritation was estimated by using ACD/Percepta QSAR model and Toxtree decision rule system
ACD/Percepta model for skin and eye irritation estimates the potential of a chemical to cause irritation in a standard rabbit Draize test. It calculates the probability for a chemical to cause moderate or above irritation to skin/eye of rabbit at a standard dose of 100 and 500 mg, respectively. Predictions provided by ACD/ Irritation probabilistic model are not supported by a specific parameter for reliability assessment.
Toxtree predicts the skin/eye irritation caused by a chemical according to the EU risk phrases (R34: Causes burns; R35: Causes severe burns; R38: Irritating to skin; R36: Irritating to eyes (moderate eye irritation reversible within ≤ 21 days); R41: Risk of serious damage to eyes (moderate but persistent eye lesions, eye corrosion)), based on physicochemical property exclusion rules and structural inclusion rules.

Key value for chemical safety assessment

Skin irritation / corrosion

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Eye irritation

Endpoint conclusion
Endpoint conclusion:
no adverse effect observed (not irritating)

Respiratory irritation

Endpoint conclusion
Endpoint conclusion:
no study available

Additional information

Skin irritation

ACD/Percepta predicted 2-phenyl-2-(pyridin-2-yl)acetamide as not skin irritant, with a probability to cause skin irritation equal to 0.32. ACD/Percepta displays up to 5 most similar structures from the training set along with experimental results. The information on analogues was used to assess the reliability of the prediction, since it illustrates how the test compound is represented in the training set.

Only one compound, 3-Nicotinamide, was identified as analogue of 2-phenyl-2-(pyridin-2- yl)acetamide, with similarity greater than 0.5 and consistent negative experimental Draize test result. Since only one compound with similarity greater than 0.5 was identified, ACD/Percepta prediction for 2-phenyl-2 -(pyridin-2-yl)acetamide was assessed as borderline reliable.

Toxtree predicted the target 2-phenyl-2-(pyridin-2-yl)acetamide as not skin irritant since it didn’t fulfil any inclusion rule while it fulfilled the exclusion rules due to the fact that the target belongs to the class of chemicals containing Carbon (C), Hydrogen (H), Oxygen (O) and Nitrogen (N) atoms with Vapour Pressure < 0.001 Pa (selected vapour pressure estimated by EPISuite/MPBPVP = 0.0000834 Pa). A detailed assessment of the reliability of the prediction is not provided by Toxtree.

Eye irritation

ACD/Percepta predicted 2-phenyl-2-(pyridin-2-yl)acetamide as not eye irritant, with a probability to cause eye irritation equal to 0.30. ACD/Percepta displays up to 5 most similar structures from the training set along with experimental results. The information on analogues was used to assess the reliability of the prediction, since it illustrates how the test compound is represented in the training set.

Only one compound, 3 -Nicotinamide, was identified as analogue of 2-phenyl-2-(pyridin-2 -yl)acetamide, with similarity greater than 0.5 and a moderately irritating test result. Since only one compound with similarity greater than 0.5 was identified, ACD/Percepta prediction for 2-phenyl-2-(pyridin-2-yl)acetamide was assessed as borderline reliable.

Toxtree did not provide any prediction for the eye irritation of the target 2-phenyl-2-(pyridin-2-yl)acetamide, since the target does not fulfil any inclusion rule nor exclusion rule.


Justification for selection of skin irritation / corrosion endpoint:
Skin irritation was estimated by using ACD/Percepta QSAR model and Toxtree decision rule system.

Justification for selection of eye irritation endpoint:
Eye irritation was estimated by using ACD/Percepta QSAR model and Toxtree decision rule system.

Justification for classification or non-classification

The two predictors were employed in order to apply a weight of evidence approach to enhance the reliability of the prediction.

For the skin irritation, the two predictors were in agreement leading to the conclusion that the target 2-phenyl-2-(pyridin-2-yl)acetamide is predicted as NOT SKIN IRRITANT, and the prediction was assessed as borderline reliable.

For the eye irritation, since Toxtree prediction did not provide any prediction, based on ACD/Percepta prediction it was concluded that the target 2-phenyl-2-(pyridin-2-yl)acetamide is predicted as NOT EYE IRRITANT, and the prediction was assessed as borderline reliable.