Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
explosiveness, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24. 6. - 3. 7. 2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2015

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
Trisodium 5-[[4-[[4-[[4-[(4-amino-9,10-dihydro-9,10-dioxo-3-sulphonato-1-anthryl)amino]-2-sulphonatophenyl]amino]-6-(phenylamino)-1,3,5-triazin-2-yl]amino]phenyl]azo]salicylate
EC Number:
229-309-0
EC Name:
Trisodium 5-[[4-[[4-[[4-[(4-amino-9,10-dihydro-9,10-dioxo-3-sulphonato-1-anthryl)amino]-2-sulphonatophenyl]amino]-6-(phenylamino)-1,3,5-triazin-2-yl]amino]phenyl]azo]salicylate
Cas Number:
6471-09-6
Molecular formula:
C42H30N10O11S2.3Na
IUPAC Name:
trisodium 5-[[4-[[4-[[4-[(4-amino-9,10-dihydro-9,10-dioxo-3-sulphonato-1-anthryl)amino]-2-sulphonatophenyl]amino]-6-(phenylamino)-1,3,5-triazin-2-yl]amino]phenyl]azo]salicylate
Test material form:
solid: particulate/powder

Results and discussion

Small-scale preliminary testsopen allclose all
Key result
Parameter:
thermal sensitivity - Koenen test: diameter of the orifice plate
Remarks on result:
not thermal sensitive if heated under defined confinement
Key result
Parameter:
sensitiveness to impact: impact energy (J)
Remarks on result:
not sensitive to impact using an impact energy of 40 J
Key result
Parameter:
sensitiveness to friction: friction load (N)
Remarks on result:
not sensitive to friction using a friction load of 360 N

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance is not sensitive with respect to heating, shock and friction. The test substance, Direct Green 28, has not explosive properties.