Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Version / remarks:
May 31, 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: VDI 223: Test Methods for the Determination of the Safety Characteristic of Dusts
Version / remarks:
May 1990
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
1,1'-[methylenebis(sulphonyl)]diethylene
EC Number:
221-909-0
EC Name:
1,1'-[methylenebis(sulphonyl)]diethylene
Cas Number:
3278-22-6
Molecular formula:
C5H8O4S2
IUPAC Name:
(ethenesulfonyl)methanesulfonylethene
Test material form:
solid: particulate/powder
Details on test material:
white crystalline powder

Results and discussion

Flammable solids
Test procedure:
burning rate test: preliminary screening test
Burning time:
<= 2 s

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The preliminary screening test was performed for the determination of the flammability of CH02241.
No propagation of combustion of the test item along 200 mm length of the pile within
4 minutes was observed. According to the guidelines, performance of the burning rate test is not required. Based on the results obtained, the test item is considered ‘not highly flammable’.