Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Study period:
7 - 9 Nov 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.11 (Flammability (Gases))
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
1,1,1,2,3,3-hexafluoro-2-(heptafluoropropoxy)-3-[(trifluorovinyl)oxy]propane
EC Number:
216-703-2
EC Name:
1,1,1,2,3,3-hexafluoro-2-(heptafluoropropoxy)-3-[(trifluorovinyl)oxy]propane
Cas Number:
1644-11-7
Molecular formula:
C8F16O2
IUPAC Name:
1,1,1,2,2,3,3-heptafluoro-3-({1,1,1,2,3,3-hexafluoro-3-[(1,2,2-trifluoroethenyl)oxy]propan-2-yl}oxy)propane
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: 116B2018
- Physical state: colourless liquid
- Purity:96.7%
- Purity test date: 9 August 2016
- Expiration date of the lot/batch: 31 March 2018

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature (10 °C to 30 °C)

Results and discussion

Flammable gases (Lower and upper explosion limit)open allclose all
Key result
Parameter:
lower explosion limit
Remarks on result:
no flammable range with air at 20°C and 101.3 kPa
Parameter:
upper explosion limit
Remarks on result:
no flammable range with air at 20°C and 101.3 kPa

Any other information on results incl. tables

Starting at 0.5 mol-% of test item and proceeding up to 4.0 mol-% of test item, no ignition was observed. For the mixtures from 2.5 to 4.0 mol-% of test item, a formation of aerosol in the static mixer was observed.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
In a flammability test of PPVE-2, no ignition was observed according to EU Method A.11.
Executive summary:

The flammability of PPVE-2 was evaluated according to EU Method A.11. This test was performed following EU guidance and was GLP compliant; therefore it is considered reliable without restriction.