Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
pyrophoric liquids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
other:
Interpretation of results:
not classified based on GHS criteria
Endpoint:
self-heating substances / mixtures
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Interpretation of results:
not classified based on GHS criteria
Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
Interpretation of results:
not classified based on GHS criteria

Description of key information

The endpoints are waived:

Flammability:Test A10: Test is only applicable for solids. The commercial substance is a liquid. Test A12: water reactivity: Based on the molecular structure as well as experience in handling and use shows that the substance has no water reactive properties. Test A13: pyrophoric properties: Based on the molecular structure as well as experience in in handling and use shows that the substance has no pyrophoric properties.

According to ECHA Guidance on information requirements and chemical safety assessment. Chapter R.7a: Endpoint specific guidance p 120.

Self -heating:The commercial substance is a liquid and therefore not self-heating. The pure substance has a melting point of 33°C, so can also waived because it is a solid with mp < 160°C.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The endpoints are waived:

Flammability:Test A10: Test is only applicable for solids. The commercial substance is a liquid. Test A12: water reactivity: Based on the molecular structure as well as experience in handling and use shows that the substance has no water reactive properties. Test A13: pyrophoric properties: Based on the molecular structure as well as experience in in handling and use shows that the substance has no pyrophoric properties.

According to ECHA Guidance on information requirements and chemical safety assessment. Chapter R.7a: Endpoint specific guidance p 120.

Self -heating:The commercial substance is a liquid and therefore not self-heating. The pure substance has a melting point of 33°C, so can also waived because it is a solid with mp < 160°C.