Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
not specified
Type of method:
other: Pensky-Martens closed cup method
Flash point apparatus:
Setaflash apparatus
Remarks:
Seta Multiflash flash point test from Petrotest, Modul No.34000-0
Dynamic viscosity of test material:
Batch no.: #120039110
Identity: carbamic acid, butylester (93.5 %), n-butanol (2.7%), ?n-Butylcarbamoyl carbamate (2.2 %), dibutyl carbonate (1.2 %)
Key result
Flash point:
98.5 °C
Atm. press.:
1 atm
Interpretation of results:
other: CLP criteria not met
Remarks:
does not need to be classified
Conclusions:
Under the study conditions, the flash-point of the test substance was determined to be 98.5°C.
Executive summary:

A study was conducted to determine the flash-point of the test substance, according to ISO 2719 (Pensky-Martens closed cup method) as described in EU Method A.9. A Seta Flash apparatus was used in this experiment. Under the study conditions, the flash-point of the test substance was determined to be 98.5°C (Sohar, 2016).

Description of key information

The flash point was determined according to ISO 2719 (Pensky-Martens closed cup method) as described in EU Method A.9 (Sohar, 2016).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
98.5 °C