Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 2018-01-29 to 2018-03-30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
GLP compliance:
yes
Type of method:
effusion method: Knudsen cell
Specific details on test material used for the study:
Batch No.: 20170707
Purity: 99.13%
Key result
Test no.:
#1
Temp.:
114 °C
Vapour pressure:
9.792 Pa
Key result
Test no.:
#2
Temp.:
116 °C
Vapour pressure:
10.755 Pa
Key result
Test no.:
#3
Temp.:
118 °C
Vapour pressure:
12.056 Pa
Key result
Test no.:
#4
Temp.:
120 °C
Vapour pressure:
13.28 Pa
Key result
Temp.:
20 °C
Vapour pressure:
0.015 Pa
Remarks on result:
other: Extrapolated to 20°C
Conclusions:
The vapor pressure of test item extrapolated to 20°C is 0.014955 Pa.
Executive summary:

The vapor pressure of the test substance by Knudsen effusion method was measured using a Surface Measurement System VPA-1, vapor pressure analyzer based on the methodology referenced in OPPTS 830.7950 and OECD 104. The Knudsen effusion method is a dynamic

gravimetric technique based on the rate of escape of vapor molecules through an orifice of known dimension in a Knudsen cell into a vacuum at a known temperature. The rate of mass loss through the orifice per unit of time was measured and used to calculate the vapor pressure. Calculations were performed using VPA Analysis: DVS Std v 7.1.0 (includes VPA analysis Software v0.6).

The vapor pressure of test item extrapolated to 20°C is 0.014955 Pa.

Description of key information

The vapor pressure of test item extrapolated to 20°C is 0.014955 Pa.

Key value for chemical safety assessment

Vapour pressure:
0.015 Pa
at the temperature of:
20 °C

Additional information