Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Data from experimental study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Principles of method if other than guideline:
The flash point determination of test material was done. The method is closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
87.3 °C
Atm. press.:
973 hPa
Remarks on result:
other: No other detail available
Interpretation of results:
GHS criteria not met
Conclusions:
The mean flash point of test material is 87.3 °C at 973.0 hPa.
Executive summary:

The flash point determination of test material was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 87.3 °C at 973.0 hPa.

Description of key information

Flash point:

The flash point determination of test material was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 87.3 °C at 973.0 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
87.3 °C

Additional information

Flash point:

The flash point determination of test material was done following closed cup method using Pensky-Martens flash point apparatus. The test was conducted in replicates and mean flash point was determine to be 87.3 °C at 973.0 hPa.

From other reliable sources& authoritative databases flash point of test material using closedcup method was determined to be 118 degree C & 104 degree C.