Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
adsorption / desorption: screening
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Study period:
06 JAN 2020, recalculated using the new model on 06 OCT 2022
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
OECD QSAR toolbox v4.5

2. MODEL (incl. version number)
KOCWIN v2.01

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
CC(C)CCC(C)=O

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
please refer to QMRF attached under 'Attached justification'

5. APPLICABILITY DOMAIN
please refer to attached QPRF attached under 'Attached justification'
Guideline:
other: ECHA Guidance R.6
Version / remarks:
May 2008
Principles of method if other than guideline:
- Software tool(s) used including version: OECD QSAR toolbox v4.5, EPI Suite v4.11
- Model(s) used:
KOCWIN v2.01
- Model description: see field 'Justification for non-standard information' and 'Attached justification'
- Justification of QSAR prediction: see field 'Justification for type of information' and 'Attached justification'
Type of method:
other: QSAR (EPISUITE KOCWIN based on logKow)
Media:
other: Soils and Sediments
Specific details on test material used for the study:
CC(C)CCC(C)=O
Type:
log Koc
Value:
2.16 dimensionless
Remarks on result:
other: estimated using the logKow method (EPIWIN - KOCWIN)
Type:
Koc
Value:
144 L/kg
Remarks on result:
other: estimated using the logKow method (EPIWIN - KOCWIN)

Koc Estimate from Log Kow: -------------------------

Log Kow (User entered ) ......................... : 1.88

Non-Corrected Log Koc (0.55313 logKow + 0.9251) .... : 1.9650

Fragment Correction(s): 1 Ketone (-C-CO-C-) ................... : 0.1956

Corrected Log Koc .................................. : 2.1606

Estimated Koc: 144.7 L/kg

Validity criteria fulfilled:
yes
Conclusions:
The Koc was determined to be 144 L/kg (log Koc 2.16) using KOCWIN v2.01 (logKow method).
Executive summary:

The Koc was determined using KOCWIN v2.01 (logKow method). It revealed a value of 144 L/kg (log Koc 2.16).

Endpoint:
adsorption / desorption: screening
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Study period:
18 FEB 2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
Algorithm-ACD, Advanced Chemistry Development, Inc., Toronto, CA.

2. MODEL (incl. version number)

LogP Web Service, Version 8.02, (2009)

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL

CC(=O)CCC(C)C

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
Prediction is made using fragmental correction method. Regressions are used to establish equations.
Model algorithm/equations are proprietary to ACDLabs.

ACD labs uses a training set of >5000 compounds. The model is validated by a dataset of more than 6000 compounds.

5. APPLICABILITY DOMAIN
not specified
Guideline:
other: ECHA Guidance R.6
Principles of method if other than guideline:
- Software tool(s) used including version: Algorithm-ACD, Advanced Chemistry Development, Inc., Toronto, CA.
- Model(s) used: LogP Web Service, Version 8.02, (2009)
- Model description: see field 'Justification for non-standard information'
- Justification of QSAR prediction: see field 'Justification for type of information',
Media:
other: soils/sediments
Specific details on test material used for the study:
CC(=O)CCC(C)C
Type:
log Koc
Value:
2.3 dimensionless
Validity criteria fulfilled:
yes
Conclusions:
logKOC value of 2.3 at 25 °C was determined by the QSAR model ACDLabs.
Executive summary:

The adsorption/desorption (Log Koc) was estimated using the ACDLabs model. This yielded a logKOC value of 2.3 at 25 °C.

Endpoint:
adsorption / desorption: screening
Type of information:
(Q)SAR
Adequacy of study:
weight of evidence
Study period:
06 JAN 2020, recalculated using the new model on 06 OCT 2022
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
results derived from a valid (Q)SAR model and falling into its applicability domain, with adequate and reliable documentation / justification
Justification for type of information:
1. SOFTWARE
OECD QSAR toolbox v4.5, EPI Suite v4.11

2. MODEL (incl. version number)
KOCWIN v2.01

3. SMILES OR OTHER IDENTIFIERS USED AS INPUT FOR THE MODEL
CC(C)CCC(C)=O

4. SCIENTIFIC VALIDITY OF THE (Q)SAR MODEL
please refer to QMRF attached under 'Attached justification'

5. APPLICABILITY DOMAIN
please refer to attached QPRF attached under 'Attached justification'
Guideline:
other: ECHA Guidance R.6
Version / remarks:
May 2008
Principles of method if other than guideline:
- Software tool(s) used including version: OECD QSAR toolbox v4.5, EPI Suite v4.11
- Model(s) used: KOCWIN v2.01
- Model description: see field 'Justification for non-standard information' and 'Attached justification'
- Justification of QSAR prediction: see field 'Justification for type of information' and 'Attached justification'
Type of method:
other: QSAR (EPISUITE KOCWIN MCI)
Media:
other: soils/sediments
Specific details on test material used for the study:
CC(C)CCC(C)=O
Type:
log Koc
Value:
1.36 dimensionless
Remarks on result:
other: estimated using the MCI method (EPIWIN - KOCWIN)
Type:
Koc
Value:
22.96 L/kg
Remarks on result:
other: estimated using the MCI method (EPIWIN - KOCWIN)

KOCWIN Program (v2.01) Results: ==============================


SMILES : O=C(CCC(C)C)C


CHEM : 2-Hexanone, 5-methyl-


MOL FOR: C7 H14 O1


MOL WT : 114.19


--------------------------- KOCWIN v2.01 Results --------------------------- Koc Estimate from MCI: --------------------- First Order Molecular Connectivity Index ........... : 3.626


Non-Corrected Log Koc (0.5213 MCI + 0.60) .......... : 2.4900


Fragment Correction(s): 1 Ketone (-C-CO-C-) ................... : -1.1290


Corrected Log Koc .................................. : 1.3610 Estimated


Koc: 22.96 L/kg

Validity criteria fulfilled:
yes
Conclusions:
The Koc was determined to be 22.96 L/kg (log Koc 1.96) using KOCWIN v2.01 (MCI method).
Executive summary:

The Koc was determined using KOCWIN v2.01 (MCI method). It revealed a value of 22.96 L/kg (log Koc 1.96).

Description of key information

Estimation of adsorption/desorption (Log Koc) from three different QSAR models.

Key value for chemical safety assessment

Koc at 20 °C:
22.96

Additional information

The adsorption/desorption (Log Koc) was estimated using three different QSAR models. The ACDLabs model yielded a value of 2.3, at 25 °C. Using a Log Kow input value of 1.88, EPISUITE-KOCWIN yielded a value of 2.16 (corresponding to an estimated Koc of 144.7 L/kg), at 25 °C. Using the EPISUITE Molecular Connectivity Index Model, a value of 1.36 (corresponding to an estimated Koc of 22.96 L/kg), at 25 °C, was obtained.