Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines
Qualifier:
according to guideline
Guideline:
OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
Principles of method if other than guideline:
The partition Coefficient n-octanol/water of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 117 for testing of Chemicals.
GLP compliance:
no
Type of method:
HPLC method
Partition coefficient type:
octanol-water
Analytical method:
high-performance liquid chromatography
Key result
Type:
log Pow
Partition coefficient:
3.084
Temp.:
25 °C
pH:
3.68
Remarks on result:
other: logKow was reported to be 3.0842 ± 0.012
Details on results:
The Partition coefficient (Pow) of the test chemical was determined to be 3.0842 ± 0.012 at 25°C

Result:

Test substance

K

LogK

Log Pow by Generalized Calibration Graph

Mean of logPow ± S.D

Tr1

2.07

1.2013

0.0797

3.0760

3.0842±0.012

Tr2

2.084

1.2162

0.0850

3.0924

Conclusions:
The partition coefficient(n-octanol/water) of test substance was determined as per the HPLC method (OECD Guideline-117). The Log Pow value was determined to be 3.0842 ± 0.012 at 25°C.
Executive summary:

The partition Coefficient n-octanol/water of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 117 for testing of Chemicals. A test item solution was prepared by accurately weighing 4 mg of test item and diluted with ACN up to 10 ml. Thus, the test solution concentration was 450.4 mg/l. The pH of test substance was 3.68. The reference substances were chosen according to functional similarity with the test substance and calibration graph was prepared .The reference substances were Benzene, Biphenyl, Methyl benzoate, Benzyl Benzoate, 4-Acetylpyridine, Diphenylamine, Toluene, Ethylbenzene, n-Butylbenzene, Naphthalene having Pow value ranging from 0.5 to 4.6. The Log Pow value of the test chemical was determined to be 3.0842 ± 0.012 dimensionless at 25°C. On the basis of this value, test chemical can be considered to be hydrophilic in nature.

Description of key information

Based on the available data from study report,the partition Coefficient n-octanol/water of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 117 for testing of Chemicals. A test item solution was prepared by accurately weighing 4 mg of test item and diluted with ACN up to 10 ml. Thus, the test solution concentration was 450.4 mg/l. The pH of test substance was 3.68. The reference substances were chosen according to functional similarity with the test substance and calibration graph was prepared .The reference substances were Benzene, Biphenyl, Methyl benzoate, Benzyl Benzoate, 4-Acetylpyridine, Diphenylamine, Toluene, Ethylbenzene, n-Butylbenzene, Naphthalene having Pow value ranging from 0.5 to 4.6. The Log Pow value of the test chemical methyl-N-methylanthranilate was determined to be 3.0842 ± 0.012 dimensionless at 25°C. On the basis of this value, test chemical can be considered to be hydrophilic in nature.

Key value for chemical safety assessment

Log Kow (Log Pow):
3.08
at the temperature of:
25 °C

Additional information

Based on the available data in a key study from study report, the partition Coefficient n-octanol/water of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 117 for testing of Chemicals. A test item solution was prepared by accurately weighing 4 mg of test item and diluted with ACN up to 10 ml. Thus, the test solution concentration was 450.4 mg/l. The pH of test substance was 3.68. The reference substances were chosen according to functional similarity with the test substance and calibration graph was prepared .The reference substances were Benzene, Biphenyl, Methyl benzoate, Benzyl Benzoate, 4-Acetylpyridine, Diphenylamine, Toluene, Ethylbenzene, n-Butylbenzene, Naphthalene having Pow value ranging from 0.5 to 4.6. The Log Pow value of the test chemical methyl-N-methylanthranilate was determined to be 3.0842 ± 0.012 dimensionless at 25°C.

Additional study from peer reviewed journal, authoritative and modelling database indicates that the octanol water partition coefficient (log Pow) value of the test chemical was estimated to be 2.81.

Thus, based on the available information, the logPow valueof the test chemical ranges from 2.81 to 3.08, respectively. On the basis of this value, test chemical can be considered to behydrophilic in nature.