Administrative data

First-aid measures

General Advice - No hazards which require special first aid measures

If inhaled - Remove from exposure, lie down. If breathing is irregular or stopped, administer artificial respiration. Monitor breathing, give oxygen if necessary. Consult a physician

In case of skin contact - Wash off with soap and water

In case of eye contact - Rinse with plenty of water

If swallowed - Consult a physician if necessary. Rinse mouth

Description of first aid measures - general advice

Most important symptoms and effects, both acute and delayed - No information available.

Indication of any immediate medical attention and special treatment needed -  No information available

Fire-fighting measures

Suitable extinguishing media - Water, Foam, Dry powder, Carbon dioxide (CO2)

Special hazards arising from the substance or mixture during firefighting - Dangerous gases or fumes may occur in case of fire

Special protective equipment for firefighters - Wear self contained breathing apparatus for fire fighting if necessary

Further information for firefighters - Use extinguishing measures that are appropriate to local circumstances and the surrounding environment

Accidental release measures

Personal precautions  Handle in accordance with good industrial hygiene and safety practice

Special precautions - Forms slippery/greasy layers with water

Environmental precautions - Avoid subsoil penetration. Do not flush into surface water or sanitary sewer system

Methods for cleaning up - Use mechanical handling equipment. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust)

Handling and storage

Advice on safe handling - No special technical protective measures required

Advice on protection against fire and explosion - Normal measures for preventive fire protection

Requirements for storage areas and containers - No special storage conditions required

Storage class (TRGS 510) - 10: Combustible liquids not in Storage Class 3

Other data - Protect from frost, heat and sunlight

Specific use(s) - This information is not available

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not dangerous goods
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not dangerous goods
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not dangerous goods
Shipping information
Proper shipping name and description:
Not dangerous goods
Chemical name:
Not dangerous goods
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not dangerous goods
Shipping information
Proper shipping name and description:
Not dangerous goods
Chemical name:
Not dangerous goods
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

PERSONAL PROTECTIVE EQUIPMENT

Respiratory protection  - No personal respiratory protective equipment normally required. In inadequately ventilated areas, where workplace limits are exceeded, where unpleasant odours exist or where aerosols are in use, or smoke and mist occur, use self-contained breathing apparatus or breathing apparatus with a type A filter or appropriate combined filter (e.g. where aerosols are in use, or smoke and mist occur, A-P2 or ABEK-P2), in compliance with EN 141

Hand protection – Not specified

Eye protection - Safety glasses

Skin and body protection-  Protective suit

Hygiene measures - General industrial hygiene practice

Protective measures - No special protective equipment required

Stability and reactivity

Reactivity - Stable at normal ambient temperature and pressure. No decomposition if stored and applied as directed

Chemical Stability - No decomposition if stored and applied as directed

Hazardous reactions - None known

Conditions to avoid - Direct heating, dirt, chemical contamination, sunlight, UV or ionising radiation

Materials to avoid - None known

Hazardous decomposition products - No decomposition if stored normally

Thermal decomposition - No decomposition if used as directed

Disposal considerations

Product - Can be incinerated, when in compliance with local regulations

Contaminated packaging-  Empty remaining contents

Waste code of the European Union: EWCA - waste code in accordance with the European Waste Catalogue (EWC) may not be assigned to this product since it admits of a classification only when the consumer uses it for some purpose. The waste code must be determined in agreement with the regional waste disposal authority or company