Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study, OECD guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Report date:
2010

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance

Test material

Constituent 1
Reference substance name:
LCE 10027
IUPAC Name:
LCE 10027
Details on test material:
Identification LCE10027
Identification of the flask LCE10027; LOT: T92235
Batch T92235
Expiry date Not provided
Supplier SEPPIC
Appearance Beige Pearls
Packaging 1 White plastic flask with blue stopper
Quantity received 1 x 300 g
Date of the receipt 15 March 2010
Storage In darkness at room temperature
Identification number of the test item 10-041

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
1.7 Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of LCE10027 extrapolated at 25 °C is 1.7 x 10-3 Pa.
Executive summary:

In compliance with Commission Regulation (EC) No. 761/2009 - EC A4 method (2009) and OECD Guideline No. 104 (2006)