Physical & Chemical properties

Additional physico-chemical information

Administrative data

Endpoint:
other: corrosive to metals
Type of information:
other: expert statement
Adequacy of study:
key study
Study period:
April 24th, 2013
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
An expert statement has been issued for this end point taking into consideration the pH value of the aqueous solution containing the test substance, its storage and transport conditions as well as the long term handling experience of the test substance.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: Test in Part III, sub-section 37.4 of the UN Recommendations on the Transport of Dangerous Goods, of the Manual of Tests and Criteria
Deviations:
no
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of 2,2'-[(4-methylphenyl)imino]bisethanol and Ethanol 2-[[2-(2-hydroxyethoxy)ethyl](4-methylphenyl)amino]-
EC Number:
911-490-9
Molecular formula:
not applicable
IUPAC Name:
Reaction mass of 2,2'-[(4-methylphenyl)imino]bisethanol and Ethanol 2-[[2-(2-hydroxyethoxy)ethyl](4-methylphenyl)amino]-
Test material form:
liquid: viscous
Details on test material:
No information available.

Results and discussion

Applicant's summary and conclusion

Conclusions:
Based on the fact that aqueous solution of the test substance indicates a pH in the range of 7-9 (see Section 4.8, water solubility determination, pH of aq. solution was determined to be 8.7), being stored and transport in steel containers at room temperature and based on long term experience of test substance handling, the test substance is assigned to be not corrosive to metals.