Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

5.1 Extinguishing media
Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Unsuitable extinguishing
media
: High volume water jet
5.2 Special hazards arising from the substance or mixture
Specific hazards during firefighting
: Do not allow run-off from fire fighting to enter drains or water
courses.
Hazardous combustion products
: Ammonia
Carbon oxides
Hazardous decomposition products due to incomplete combustion
Metal oxides
5.3 Advice for firefighters
Special protective equipment
for firefighters
: No special protective equipment required.
Further information : Collect contaminated fire extinguishing water separately. This
must not be discharged into drains.
Fire residues and contaminated fire extinguishing water must
be disposed of in accordance with local regulations.

Fire-fighting measures

5.1 Extinguishing media

Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable extinguishing

media

: High volume water jet

5.2 Special hazards arising from the substance or mixture

Specific hazards during firefighting

: Do not allow run-off from fire fighting to enter drains or water

courses.

Hazardous combustion products

: Ammonia

Carbon oxides

Hazardous decomposition products due to incomplete combustion

Metal oxides

5.3 Advice for firefighters

Special protective equipment

for firefighters

: No special protective equipment required.

Further information : Collect contaminated fire extinguishing water separately. This

must not be discharged into drains.

Fire residues and contaminated fire extinguishing water must

be disposed of in accordance with local regulations.

Accidental release measures

6.1 Personal precautions, protective equipment and emergency procedures
Personal precautions : Use personal protective equipment.
Avoid dust formation.
Avoid breathing dust.
6.2 Environmental precautions
Environmental precautions : Prevent product from entering drains.
Prevent further leakage or spillage if safe to do so.
If the product contaminates rivers and lakes or drains inform
respective authorities.
6.3 Methods and material for containment and cleaning up
Methods for cleaning up : Wipe up with absorbent material (e.g. cloth, fleece).


6.4 Reference to other sections

Handling and storage

7.1 Precautions for safe handling
Advice on safe handling : Avoid formation of respirable particles.
Do not breathe vapours/dust.
Avoid contact with skin and eyes.
For personal protection see section 8.
Smoking, eating and drinking should be prohibited in the application area.
Advice on protection against
fire and explosion
: Provide appropriate exhaust ventilation at places where dust
is formed.
Hygiene measures : General industrial hygiene practice. Wash hands before
breaks and at the end of workday.
7.2 Conditions for safe storage, including any incompatibilities
Requirements for storage
areas and containers
: Keep container tightly closed in a dry and well-ventilated
place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Electrical installations / working materials must comply with the technological
safety standards. To maintain product quality, do not store in
heat or direct sunlight.
Storage class (TRGS 510) : 13, Non Combustible Solids
Further information on storage stability
: Keep in a dry place.
No decomposition if stored and applied as directed.
7.3 Specific end use(s)

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

8.2 Exposure controls
Engineering measures
Handle only in a place equipped with local exhaust (or other appropriate exhaust).
Personal protective equipment
Eye protection : Wear safety glasses with side shields or goggles.
Hand protection
Material : Nitrile rubber
Break through time : 240 min
Glove thickness : 0,38 mm
Manufacturer : Mapa
Skin and body protection : Footwear protecting against chemicals
Respiratory protection : In the case of dust or aerosol formation use respirator with an
approved filter.
Filter type : Combined particulates, inorganic and acidic gas/vapour,
ammonia/amines and organic vapour type (ABEK-P)
In case of inadequate ventilation wear respiratory protection.

Stability and reactivity

10.1 Reactivity
10.2 Chemical stability
No decomposition if stored and applied as directed.
10.3 Possibility of hazardous reactions
Hazardous reactions : Stable under recommended storage conditions.
10.4 Conditions to avoid
10.5 Incompatible materials
10.6 Hazardous decomposition products

Disposal considerations

13.1 Waste treatment methods
Product : Dispose of in accordance with the European Directives on
waste and hazardous waste.
According to the European Waste Catalogue, Waste Codes
are not product specific, but application specific.
Waste codes should be assigned by the user, preferably in
discussion with the waste disposal authorities.
The product should not be allowed to enter drains, water
courses or the soil.
Do not contaminate ponds, waterways or ditches with chemical or used container.
Send to a licensed waste management company.
Dispose of as hazardous waste in compliance with local and
national regulations.
Contaminated packaging : Empty remaining contents.
Dispose of contaminated packaging as if unused product.
Do not re-use empty containers.