Registration Dossier

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Test procedure:
burning time (test type not further specified)
Burning time:
> 1 s

The test sample was seen to ignite but the reaction did not propagate.

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
In a study performed to EC method A10, SLMI did not propagate a flame and is therefore not classified for flammability

Description of key information

In a study performed to EC method A10, SLMI did not propagate a flame and is therefore not highly flammable

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

In a study performed to EC method A10, SLMI did not propagate a flame and is therefore not highly flammable

Justification for classification or non-classification

In a study performed to EC method A10, SLMI did not propagate a flame and is therefore not classified for flammability