Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes
Relative self-ignition temperature:
> 400 °C
Remarks on result:
other:
Remarks:
at atm. press. of 1.0 atm
Conclusions:
In a study performed to EC testing method A16 SLMI was found to have a relative self-ignition temperature of >400°C at 1atm

Description of key information

In a study performed to EC method A16, SLMI had a auto flammability of >400°C at 1 atm

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
400 °C

Additional information