Registration Dossier

Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Conducted according to standard however not under GLP
Qualifier:
according to guideline
Guideline:
other: ASTM D 5950
Deviations:
no
GLP compliance:
no
Type of method:
pour point
Key result
Melting / freezing pt.:
-60 °C
Atm. press.:
1 atm
Decomposition:
no
Sublimation:
no
Conclusions:
The measured pour point is -60°C according to ASTM D 5950 methodology.
Executive summary:

The pour point of the substance Hydrocarbons, C14-C19, isoalkanes, cyclics, <2% aromatics has been measured at -60°C at 1 atm according to the ASTM D 5950 methodology.

Description of key information

The pour point of the substance Hydrocarbons, C14 -C19, isoalkanes, cyclics, <2% aromatics is less than -20°C at 1 atm according to the ASTM D 5950 methodology.

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
-60 °C

Additional information