Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
not specified
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
122.1 °C
Atm. press.:
99.9 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
A sample of test material provided a flashpoint of 122.1°C (at 99.9 kPa), using a method in accordance with ASTM D93-10.

Description of key information

Study available conducted using closed cup standard method

Key value for chemical safety assessment

Flash point at 101 325 Pa:
122.1 °C

Additional information