Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Conducted at GLP-accredited facility to current guidelines

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance

Test material

Constituent 1
Details on test material:
Test was performed with sample Lot number: MF2b_S1_06

Results and discussion

Vapour pressure
Temp.:
ca. 25 °C
Vapour pressure:
ca. 0.49 Pa

Applicant's summary and conclusion

Conclusions:
The vapour pressure of the test material has been determined to be 4.9 x 10 -E01 Pa at 25°C.
Executive summary:

The vapour pressure of the test material has been determined to be 4.9 x 10 -E01 Pa at 25°C.