Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D-93
Principles of method if other than guideline:
Pensky Martens c.c.
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
> 93.3 °C
Atm. press.:
ca. 1 013 hPa

For two samples, no flash occured during heating to 104.4 °C (220 °F). To allow a margin of safety, flash point is reported as greater than 93.3 °C (200 °F). Experiment is assumed to be performed under ambient pressure.

Interpretation of results:
GHS criteria not met

Description of key information

> 93.3 °C under ambient pressure

Key value for chemical safety assessment

Flash point at 101 325 Pa:
93.3 °C

Additional information

Pensky - Martens closed cup (ASTM D-93). Catalogue data (> 110 °C) is supporting.