Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
oxidising liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24-07-2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.21 (Oxidising Properties (Liquids))
GLP compliance:
no
Key result
Sample tested:
other: The structure of the test item was assessed
Remarks:
The structure of the test item was assessed for chemical groups that would imply oxidising properties. Full structual details are given in litterature.
Parameter:
other: Assessment
Result:
ca. 0 other: not oxidising
Remarks on result:
other: The structure of the test item was assessed
Remarks:
The structure of the test item was assessed for chemical groups that would imply oxidising properties. Full structual details are given in litterature.

Based on the negative chemical structure the result for the oxidising properties has been predicted negative.

Interpretation of results:
other: no oxidising properties
Remarks:
Migrated information
Conclusions:
Based on the negative chemical structure the result for the oxidising properties has been predicted negative.

Description of key information

Based on the negative chemical structure the result for the oxidising properties has been predicted negative.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Justification for classification or non-classification