Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
02-12-2017 – 02-12-2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
Experimental test result performed using standard test guidelines
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Principles of method if other than guideline:
The flash point determination of Test item was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material: 3-(5,5,6-trimethylbicyclo[2.2.1]hept-2-yl)cyclohexan-1-ol
- IUPAC name: 3-(5,5,6-Trimethylbicyclo[2.2.1]hept-2-yl)cyclohexan-1-ol
- Molecular formula: C16H28O
- Molecular weight: 236.396 g/mole
- Smiles :O[C@@H]1CCC[C@@H]([C@@H]2[C@@H]3C[C@@H](C(C)(C)[C@@H]3C)C2)C1
- Inchl: 1S/C16H28O/c1-10-14-8-12(16(10,2)3)9-15(14)11-5-4-6-13(17)7-11/h10-15,17H,4-9H2,1-3H3
- Substance type: Organic
- Physical state: viscous liquid
Key result
Flash point:
120 °C
Atm. press.:
973.5 hPa
Remarks on result:
other: by closed cup method

Method Details

 

Observations

Remarks if,

any

Method

Closed cup method

 

 

Principle of Flash point

test

The flash point of a flammable

liquid is the lowest temperature at

which there will be enough

flammable vapor to ignite when an

ignition source is applied.

 

Type of method

·        

 

Flash point apparatus

·        

·        

Pensky-Martens flash point apparatus

Quantity of chemical

used

g/ml

5ml

Ignition source

Gas lighter/flame

Gas lighter

Atmospheric pressure

hPa

973.5hPa

meanFlash point

(RESULT)

°C

120°C

Interpretation of results:
other: non flammable
Conclusions:
The mean flash point of test chemical was 120°C at 973.5 hPa
Executive summary:

The flash point determination of Test item was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The test was conducted in replicates and mean flash point was determined to be 120°C at 973.5 hPa.

Description of key information

The mean flash point of test chemical was 120°C at 973.5 hPa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
120 °C

Additional information

The flash point determination of Test item was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus. The test was conducted in replicates and mean flash point was determined to be 120°C at 973.5 hPa.

Other supporting data from another experimental report, also determined the flash point of test chemical by the closed cup method as 115 deg C at 760 hPa, closer to the selected key study value.

Thus accroding to the experimental values the given chemical was not classified as flammable.