Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 2003-June 2004
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: CIPAC Method MT 187
Deviations:
no
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D90
Mean:
15.74 µm
Remarks on result:
other: no St. dev. provided
Percentile:
D10
Mean:
0.74 µm
Remarks on result:
other: no St. dev. provided
Percentile:
D50
Mean:
4.31 µm
Remarks on result:
other: no St. dev. provided

Samples from nine batches have been tested. The average values for D10, D50 and D90 obtained from nine samples are summarised.

Description of key information

Particle size percentile mean:
D10 0.74 µm
D50 4.31 µm
D90 15.74 µm

Additional information