Registration Dossier

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Hydrolysis rate: no hydrolysis observed at pH 4, 7 and 9
Hydrolysis observed > 10% at PH 2
T ½ (25°C) > 1 year for pH 4, 7 and 9

Key value for chemical safety assessment

Additional information

Liquid chromatography with a mass spectrometer is used to determine the hydrolysis rate of the test item.

 

With LC/MS a direct method is used t0 measure the amounts of Mono- and Diester, which will remain after incubation in case of hydrolysis. No decreases > 10% of Mono- and Diester have been detected at pH 4, 7 and 9. At pH 2 the expected hydrolysis takes place.

 

Therefore the hydrolysis rate of the test item is

 

Hydrolysis rate: no hydrolysis observed at pH 4, 7 and 9

Hydrolysis observed > 10% at PH 2

T ½ (25°C) > 1 year for pH 4, 7 and 9