Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
activated sludge respiration inhibition testing
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2007
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
reaction mass of (2S,5R)-2-tert-butyl-5-methyl-2-propyl-2,5-dihydrofuran and (2S,5S)-2-tert-butyl-5-methyl-2-propyl-2,5-dihydrofuran
EC Number:
700-103-7
Molecular formula:
C12H22O
IUPAC Name:
reaction mass of (2S,5R)-2-tert-butyl-5-methyl-2-propyl-2,5-dihydrofuran and (2S,5S)-2-tert-butyl-5-methyl-2-propyl-2,5-dihydrofuran
Test material form:
other: liquid
Details on test material:
Batch No. LQC701302
Purity 98.1%
Expiry date October 18, 2009

Test solutions

Vehicle:
no

Test organisms

Test organisms (species):
activated sludge of a predominantly domestic sewage

Study design

Test type:
static
Limit test:
yes
Total exposure duration:
3 h

Results and discussion

Effect concentrations
Duration:
3 h
Dose descriptor:
EC50
Effect conc.:
> 1 000 mg/L
Nominal / measured:
nominal
Conc. based on:
test mat.
Basis for effect:
inhibition of total respiration
Remarks:
respiration rate

Applicant's summary and conclusion

Validity criteria fulfilled:
yes
Conclusions:
Based on measured inhibition rates, the 3-hour EC50 could not be quantified because up to the highest nominal test concentration of 1000 mg/L less than 50% inhibition was noted after three hours incubation. Nevertheless, the 3-hour EC50 is clearly higher than 1000 mg/L under the present test conditions.