Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
112.6 °C
Atm. press.:
96 980 Pa

Observation Table :

 Method Details    Observations  Remarks if, any
 Method

 The flash point of a flammable

liquid is the lowest temperature at

which there will be enough

flammable vapor to ignite when an

ignition source is applied.

                        
 Type of method  Closed cup  
Flash point apparatus

 Abel’s flash pt apparatus

Pensky-Martens flash point

apparatus

 

Pensky-Martens flash

point apparatus

Quantity of chemical

used

 g/ml

5ml 

Ignition source 

 Gas lighter/flame

 

 Atmospheric pressure

 hPa

 969.8 hPa

Mean Flash point

(RESULT)

 °C

 112.6°C

Interpretation of results:
other: non flammable
Conclusions:
The flash point of test chemical was determined to be 112°C at 96980 Pa.
Executive summary:

The flash point of test chemical was determined. The experiment was performed by closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test chemical was determined to be 112°C at 96980 Pa

Description of key information

Based on the available data from study report,the flash point of test chemical was determined. The experiment was performed by closed cup method using Pensky Martin’s Flash Point Apparatus. The flashpoint of the test chemical was determined to be 112°C at 96980 Pa

Key value for chemical safety assessment

Flash point at 101 325 Pa:
112 °C