Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

· Description of first aid measures:

· General information: No special measures required.

· After inhalation: Supply fresh air; consult doctor in case of complaints.

· After skin contact: Generally the product does not irritate the skin.

· After eye contact: Rinse opened eye for several minutes under running water.

· After swallowing: If symptoms persist consult doctor.

· Information for doctor:

· Most important symptoms and effects, both acute and delayed No further relevant information available.

· Indication of any immediate medical attention and special treatment needed

No further relevant information available.

Fire-fighting measures

· Extinguishing media:

· Suitable extinguishing agents:

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

· Special hazards arising from the substance or mixture No further relevant information available.

· Advice for firefighters

· Protective equipment: No special measures required.

Accidental release measures

· Personal precautions, protective equipment and emergency procedures: Avoid formation of dust.

· Environmental precautions: Do not allow to enter sewers/ surface or ground water.

· Methods and material for containment and cleaning up: Pick up mechanically.

No dangerous substances are released.

Handling and storage

· Handling:

· Precautions for safe handling No special measures required.

· Information about fire - and explosion protection: The product is not flammable.

· Conditions for safe storage, including any incompatibilities

· Storage:

· Requirements to be met by storerooms and receptacles: No special requirements.

· Information about storage in one common storage facility: Not required.

· Further information about storage conditions: None.

· Specific end use(s): No further relevant information available.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not applicable
Shippingopen allclose all
Labels:
Not applicable
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not applicable.
Shippingopen allclose all
Labels:
Not applicable.
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not applicable.
Shipping information
Proper shipping name and description:
Not applicable.
Chemical name:
Not applicable.
Labels:
Not applicable.
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not applicable.
Shipping information
Proper shipping name and description:
Not applicable.
Chemical name:
Not applicable.
Labels:
Not applicable.
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

· Additional information about design of technical facilities: No further data; see item 7.

· Control parameters

· Ingredients with limit values that require monitoring at the workplace: Not required.

· Additional information: The lists valid during the making were used as basis.

· Exposure controls

· Personal protective equipment:

· General protective and hygienic measures:

The usual precautionary measures are to be adhered to when handling chemicals.

· Respiratory protection: Not required.

· Protection of hands:

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation.

Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/

the chemical mixture.

Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation

· Material of gloves

The selection of the suitable gloves does not only depend on the material, but also on further marks of quality

and varies from manufacturer to manufacturer.

· Penetration time of glove material

The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be

observed.

· Eye protection: Not required.

· Body protection: Protective work clothing

Stability and reactivity

· Reactivity

· Chemical stability

· Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.

· Possibility of hazardous reactions Reacts with acids.

· Conditions to avoid No further relevant information available.

· Incompatible materials: Reacts with alcohols, amines, aqueous acids and alkalis.

· Hazardous decomposition products: Nitrogen oxides

Disposal considerations

· Waste treatment methods

· Recommendation Smaller quantities can be disposed of with household waste.

· Uncleaned packaging:

· Recommendation: Disposal must be made according to official regulations.