First-aid measures

Description of first aid measures

General advice : Move out of dangerous area.

Consult a physician.

Show this safety data sheet to the doctor in attendance.

If inhaled : Move to fresh air.

Consult a physician after significant exposure.

In case of skin contact : Take off contaminated clothing and shoes immediately.

Wash off with soap and plenty of water.

Immediate medical treatment is necessary as untreated

wounds from corrosion of the skin heal slowly and with

difficulty.

In case of burns apply cold water until pain subsides then

seek medical advice.

In case of eye contact : Small amounts splashed into eyes can cause irreversible

tissue damage and blindness.

In the case of contact with eyes, rinse immediately with plenty

of water and seek medical advice.

Continue rinsing eyes during transport to hospital.

Remove contact lenses.

Protect unharmed eye.

Keep eye wide open while rinsing.

If swallowed : Clean mouth with water and drink afterwards plenty of water.

Do NOT induce vomiting.

Do not give milk or alcoholic beverages.

Never give anything by mouth to an unconscious person.

Take victim immediately to hospital.

Fire-fighting measures

Extinguishing media

Suitable extinguishing

media

: Use water fog, foam, dry chemical or carbon dioxide (CO2) to

extinguish flames

Special hazards arising from the substance or mixture

Combustibility : Not classified as flammable or combustible, but will combust if

ignited.

Hazardous combustion

products

: Carbon monoxide, carbon dioxide and unburned

hydrocarbons (smoke).

Flammable properties :

See Section 9 for information on flammability.

Advice for firefighters

Protective equipment and

precautions for firefighters

: In the event of fire, wear self-contained breathing apparatus.

Fire Fighting Instructions : Collect contaminated fire extinguishing water separately. This

must not be discharged into drains.

Fire residues and contaminated fire extinguishing water must

be disposed of in accordance with local regulations.

Accidental release measures

Personal precautions,

protective equipment and

emergency procedures

: Avoid contact with spilled material. Do not touch or walk

through spilled material.

Use personal protective equipment.

Ensure adequate ventilation.

Evacuate personnel to safe areas.

Environmental precautions : Prevent entry into waterways, sewers, basements or

confined areas.

Do not flush into surface water or sanitary sewer system.

If the product contaminates rivers and lakes or drains inform

respective authorities.

Methods and materials for : Prevent further leakage or spillage if safe to do so.

containment and cleaning

up

Large Spills: Dyke far ahead of liquid spill for later recovery

and disposal.

Recover by pumping or with suitable absorbent

Report spills as required to appropriate authorities.

Seek the advice of a specialist before using dispersants.

Dispose of according to local regulations.

In the event of a spill or accidental release, notify relevant

authorities in accordance with all applicable regulations.

Material will float on water, use containment booms as a

barrier to protect shorelines.

Soak up with inert absorbent material (e.g. sand, silica gel,

acid binder, universal binder, sawdust).

Keep in suitable, closed containers for disposal.

Reference to other sections

Other information : For personal protection see section 8.

Handling and storage

Precautions for safe handling

Smoking, eating and drinking should be prohibited in the application area.

To avoid spills during handling keep bottle on a metal tray.

Dispose of rinse water in accordance with local and national regulations.

Normal measures for preventive fire protection.

Products may load from Infineum manufacturing site above the standard loading/unloading range.

Loading/unloading

temperature

: 40 °C (104 ° F) - 65 °C (149 ° F)

Viscosity @

Loading/unloading

temperature

: 410 cSt - 1.800 cSt

Static accumulator : This material is not a static accumulator.

Conditions for safe storage, including any incompatibilities

Keep container tightly closed in a dry and well-ventilated place.

Containers which are opened must be carefully resealed and kept upright to prevent leakage.

No decomposition if stored and applied as directed.

Do not reheat above: 65 °C (149 ° F)

Storage temperature : 50 °C (122 ° F) - 65 °C (149 ° F)

Incompatible materials and

coatings

: Inorganic Zinc

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
UN2586
Shipping information
Proper shipping name and description:
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
Chemical name:
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
Language:
English
Labels:
8
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
UN2586
Shipping information
Proper shipping name and description:
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
Chemical name:
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
Language:
English
Labels:
8
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
UN2586
Shipping information
Proper shipping name and description:
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
Chemical name:
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
EmS code:
F-A
Labels:
8
Special provisions / remarks
Remarks:
EmS Number 2 - S-B

Air transport (UN RTDG/ICAO/IATA)

UN number:
UN2586
Shipping information
Proper shipping name and description:
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
Chemical name:
ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric
acid
Labels:
8
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

ARYLSULPHONIC ACIDS, LIQUID with not more than 5% free sulphuric

acid

Hygiene measures : Handle in accordance with good industrial hygiene and safety

practice.

Wash hands before breaks and at the end of workday.

Environmental exposure controls

General advice : Prevent entry into waterways, sewers, basements or confined

areas.

: Do not flush into surface water or sanitary sewer system.

If the product contaminates rivers and lakes or drains inform

respective authorities.

Stability and reactivity

Reactivity

Chemical stability /

Possibility of hazardous

reactions

: Stable under normal conditions.

Conditions to avoid : Elevated temperatures. Excessive heat.

Incompatible materials : Strong oxidizing agents

Disposal considerations

Disposal recommendations based on material as supplied, Disposal must be in accordance with

applicable laws and regulations, and material characteristics at time of disposal

For the safety of persons conducting disposal, recycling or reclamation activities, refer to the

information in Section 8, Exposure control and personal protection.

Waste treatment methods

Product : The product should not be allowed to enter drains, water

courses or the soil.

Do not contaminate ponds, waterways or ditches with

chemical or used container.

Offer surplus and non-recyclable solutions to a licensed

disposal company.

Empty containers.

Empty Container Warning (where applicable): Empty containers may contain residue and can be

dangerous. Do not attempt to refill or clean containers without proper instructions. Empty drums

should be completely drained and safely stored until appropriately reconditioned or disposed.

Empty containers should be taken for recycling, recovery, or disposal through suitably qualified or

licensed contractor and in accordance with governmental regulations. DO NOT PRESSURISE,

CUT, WELD, BRAZE, SOLDER, DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT,

FLAME, SPARKS, STATIC ELECTRICITY, OR OTHER SOURCES OF IGNITION. THEY MAY

EXPLODE AND CAUSE INJURY OR DEATH.

Regulatory disposal information

European Waste Code : 13 02 XX

waste engine, gear and lubricating oils