Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point
Type of information:
migrated information: read-across based on grouping of substances (category approach)
Adequacy of study:
weight of evidence
Study period:
09 July 2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: see 'Remark'
Remarks:
GLP - Guideline study. According to the ECHA guidance document "Practical guide 6: How to report read-across and categories (March 2010)", the reliability was changed from RL1 to RL2 to reflect the fact that this study was conducted on a read-across substance.
Qualifier:
equivalent or similar to guideline
Guideline:
ISO No., other: 2719
Qualifier:
equivalent or similar to guideline
Guideline:
ISO No., other: ATM D93
Qualifier:
equivalent or similar to guideline
Guideline:
ISO No., other: IP34
Principles of method if other than guideline:
Crodaspec Test method G38900
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
other: Not specified
Key result
Flash point:
219 °C
Atm. press.:
ca. 1 013 hPa
Interpretation of results:
GHS criteria not met
Endpoint:
flash point
Type of information:
migrated information: read-across based on grouping of substances (category approach)
Adequacy of study:
weight of evidence
Study period:
11 Apr 2011
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis.
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D92
GLP compliance:
no
Type of method:
open cup
Remarks:
Cleveland open cup
Flash point apparatus:
other: Not specified
Key result
Flash point:
269 °C
Atm. press.:
ca. 1 013 hPa

Pressure was not reported. Data is estimated, because the test was conducted under ambient condition using an open cup system.

Interpretation of results:
GHS criteria not met

Description of key information

219-269 °C at ca.1013 hPa based on read-across from supporting substance (structural analogue or surrogate).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
244 °C

Additional information

The flash point for the substance Decanoic acid, mixed esters with neopentyl glycol and octanoic acid (CAS 70693 -32 -2) was determined by weight of evidence approach with two similar substances: 2,2 -dimethyl-1,3 -propanediyl dioctanoate (CAS 31335 -74 -7) and Fatty acids, C6 -18, 2,2 -dimethyl-1,3 -propanediyl esters (CAS 91031 -27 -5).