Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
other: based on USP-NF method <741>
GLP compliance:
no
Type of method:
capillary method
Key result
Melting / freezing pt.:
68 °C
Atm. press.:
1 013 hPa
Conclusions:
The melting point is 68C at 1013 hPa
Executive summary:

The melting point is 68C at 1013 hPa using test method based on USP-NF method <741>.

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D 92
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Anton Paar Model CLA 5 Automatic Cleveland Flash & Fire Point Tester
Key result
Flash point:
259 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point is 259C > 200C at 1013 hPa
Executive summary:

Flash point is 259C > 200C at 1013 hPa using Cleveland Open Cup equivalent method to ASTM D92

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion