Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16 February 1995 – 25 August 1995
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Study conducted according to Method A16 of the Commission Directive 92/69/EEC and in accordance with GLP. Study material is well characterised.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1995
Report date:
1995

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.16 (Relative Self-Ignition Temperature for Solids)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Reference substance name:
Automatically generated during migration to IUCLID 6, no data available
IUPAC Name:
Automatically generated during migration to IUCLID 6, no data available
Details on test material:
A-87439.1 pharmaceutical batch number W10111-01

Results and discussion

Any other information on results incl. tables

The test substance did not self-ignite, and no trace of it was found in the cube after the test.

Applicant's summary and conclusion

Conclusions:
Does not self-ignite