Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
surface tension
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because water solubility is below 1 mg/L at 20°C
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08 March 2017 - 26 April 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Reason / purpose for cross-reference:
reference to other study
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Version / remarks:
2014
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7840 (Water Solubility)
Version / remarks:
1998
Deviations:
no
GLP compliance:
yes
Type of method:
column elution method
Key result
Water solubility:
29.5 µg/L
Conc. based on:
test mat.
Temp.:
20 °C
pH:
>= 7.9 - <= 8.1
Remarks on result:
other: average of two runs (maximum difference=10%)
Details on results:
Mean concentration in the water samples (n=10) obtained at the flowrate of 24 mL/h was 31.0 μg/L. CV= 9.2%.
Mean concentration in the water samples (n=10) obtained at the flowrate of 12 mL/h was 28.0 μg/L. CV= 9.0%.

The coefficient of variation (CV) (n=10) was ≤ 30% at both flow rates. It demonstrated that the system was in equilibrium at all flow rates.

The maximum difference on the mean values at both flow rates was ≤ 30%.

No test substance was detected in the samples from the blank column.

Conclusions:
The water solubility at 20°C was determined to be 29.5 μg/L.
Executive summary:

The water solubility of the substance was determined using the column elution method in a GLP study according to EC A.6, OECD 105 and OPPTS 830.7840.

Quantification was performed by UPLC-MS/MS. The water solubility at 20°C was determined to be 29.5 μg/L. The pH of the aqueous samples was 7.9-8.1.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion