Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Qualifier:
according to guideline
Guideline:
other: PN-EN 1235:1999/A1:2004
Principles of method if other than guideline:
The dry sieving test is performed by sieving the tested material and measuring the solid particles remaining at the sieves if any.
GLP compliance:
no
Type of method:
sieving
No.:
#1
Size:
> 0.8 mm
Distribution:
22.46 %
No.:
#2
Size:
>= 0.7 - <= 0.8 mm
Distribution:
17.24 %
No.:
#3
Size:
>= 0.6 - <= 0.7 mm
Distribution:
18.21 %
No.:
#4
Size:
>= 0.5 - <= 0.6 mm
Distribution:
16.39 %
No.:
#5
Size:
>= 0.4 - <= 0.5 mm
Distribution:
12.4 %
No.:
#6
Size:
>= 0.3 - <= 0.4 mm
Distribution:
8.18 %
No.:
#7
Size:
>= 0.2 - <= 0.3 mm
Distribution:
4.71 %
No.:
#8
Size:
>= 0.1 - <= 0.2 mm
Distribution:
0.41 %
No.:
#9
Size:
< 0.1 mm
Distribution:
0 %

Sieve analyses [mm]

 

>0.8

≥0.7–0.8

≥0.6-0.7

≥0.5-0.6

≥0.4-0.5

≥0.3-0.4

 ≥0.2-0.3

≥0.1-0.2

<0.1

[%]

22.40

17.26

18.21

16.36

12.41

8.15

4.73

0.38

0

[%]

22.46

17.24

18.23

16.41

12.40

8.19

4.70

0.41

0

[%]

22.52

17.22

18.20

16.40

12.39

8.20

4.70

0.44

0

[%]

average

22.46

17.24

18.21

16.39

12.40

8.18

4.71

0.41

0

Conclusions:
There are no particles with aerodynamic diameter less than below 100 µm.
Executive summary:

The dry sieving test for DTPA-MnNa3 was performed acc. method PN-EN 1235:1999/A1:2004. There are no particles with aerodynamic diameter less than below 100 µm.

Description of key information

The dry sieving test for DTPA-MnNa3 was performed acc. methodPN-EN 1235:1999/A1:2004.There are no particles with aerodynamic diameter less than below 100 µm.

Additional information