Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
January - March 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Remarks:
certificate No. 17/2017/DPL
Test procedure:
burning rate test: preliminary screening test
Remarks:
After the ignition the sample charred only in the place of applying the flame of burner. The sample did not ignite. Time of applying the flame of burner: 30, 60, 120 s. Result: NEGATIVE
Burning time:
0 s
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period

Results of preliminary test

Test number

Time of burning [s]

Comments

Test-1

-

After the ignition the sample charred only in the place of applying the flame of burner. The sample did not ignite. Time of applying the flame of burner: 30, 60, 120 s.

Result: NEGATIVE

Test-2

-

Test-3

-

Interpretation of results:
not classified based on GHS criteria
Conclusions:
DTPA-MnNa3 (MnDTPA) is not highly flammable in accordance with test A.10. criteria.

Executive summary:

Flammability (solids) was performed for DTPA-MnNa3 according to method A.10 Flammability (solids).

The preliminary screening test was made to determine if, on ignition by a gas flame, propagation by burning with flame or smouldering occurs.

Since the result was negative, it was not necessary to go to the next stage of determination. DTPA-MnNa3 (MnDTPA) is not highly flammable in accordance with test A.10. criteria.


Description of key information

DTPA-MnNa3(MnDTPA) is not highly flammable in accordance with test A.10. criteria.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The target substance DTPA-MnNa3 is not highly flammable in accordance with test A.10. criteria and does not need to be classified and labeling acc. Regulation 1272/2008.