Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
26 February 1987 to 4 March 1987
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Deviations:
not specified
GLP compliance:
yes
Type of method:
determination of fibre length and diameter distributions
Type of distribution:
other: Light Diffraction
Specific details on test material used for the study:
Product designation: Monoazo Yellow TZ 2382
Identification: FAT 40224/C
Vers. 10/86 Op. 1/86
Percentile:
D50
Mean:
13.1 µm
Remarks on result:
other: No source field for Standard deviation.
No.:
#1
Size:
>= 1 - <= 1.5 µm
Distribution:
>= 96 - <= 96.6 %
No.:
#2
Size:
2 µm
Distribution:
95.1 %
No.:
#3
Size:
3 µm
Distribution:
94 %
No.:
#4
Size:
4 µm
Distribution:
92.3 %
No.:
#5
Size:
6 µm
Distribution:
88.5 %
No.:
#6
Size:
8 µm
Distribution:
81.4 %
No.:
#7
Size:
12 µm
Distribution:
57.3 %
No.:
#8
Size:
16 µm
Distribution:
33.9 %
No.:
#9
Size:
24 µm
Distribution:
7.5 %
No.:
#10
Size:
>= 32 - <= 192 µm
Distribution:
>= 0 - <= 2 %
Conclusions:
The mass median diameter of FAT 40224/C is 13.1 µm.
Executive summary:

In a GLP-compliant study with FAT 40224/C, the mass median diameter of the test substance was determined according to OECD guideline 110. The test was performed on a CILAS Granulometer Model 715 and the technique is based on the principle of light diffraction. The mass median diameter of the test substance was determined to be 13.1 µm.

Description of key information

The mass median (aerodynamic) diameter of the test substance is 13.1 µm.

Additional information

In a GLP-compliant study with FAT 40224/C, the mass median diameter of the test substance was determined according to OECD guideline 110. The test was performed on a CILAS Granulometer Model 715 and the technique is based on the principle of light diffraction. The mass median diameter of the test substance was determined to be 13.1 µm.