Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 23, 1992 - June 1, 1992
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Qualifier:
according to guideline
Guideline:
ISO No., other: ASTM D93
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point:
179 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Conclusions:
The flashpoint of the substance was determined to be 179 degrees Celsius, using a Pensky-Martens closed cup apparatus.

Description of key information

The flashpoint of the substance was determined to be 179 degrees Celsius, using a Pensky-Martens closed cup apparatus.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
179 °C

Additional information